Test laboratory

EMC Testing & Services – Your Accredited EMC Laboratory in Vienna

[Translate to EN:] Validierung

Reliable EMC testing according to international standards

Our EMC laboratory, BLUETECHNIX Lab GmbH in Vienna, a state-accredited testing facility with accreditation number 271, offers professional testing for electromagnetic compatibility (EMC) of electronic devices and systems.

We conduct tests according to current standards such as:

  • EN 50121-3-2 / EN 50121-4 – Rail
  • EN 55032 / CISPR 32 – Multimedia devices
  • EN 61000-6-x – Generic residential and industrial emission/immunity
  • EN 61000-4-x – Immunity tests: ESD / Burst / Surge / Magnetic field / RF immunity tests
  • EN 60601-1-2 – Medical technology
  • CISPR 25 / ISO 7637 / ISO 11452-x – Automotive components: emission and immunity
  • Automotive manufacturer standards – MBN, BMW, VW, etc.
  • ISO 16750-2 / LV 124 / LV 148 – Electrical tests (also with climate chamber)
  • ISO 10605 – Automotive ESD
  • CISPR 25 / ISO 11451-x – Automotive vehicle measurements – Pre-Compliance
  • MIL-STD 461 – (Pre)-Compliance measurements
  • EMVU – Pre-Compliance, e.g., ICNIRP 98: 0 Hz – 400 kHz
  • Accredited standards scope – see accredited testing laboratory 271: akkreditierung-austria.gv.at/overview (enter 271 under “Accredited body”)

 

divider

Why choose our EMC laboratory in Vienna?

  • Accredited according to ISO/IEC 17025
  • Experienced team of EMC specialists with expertise in EMC debugging and simulation
  • Fast appointment scheduling & transparent processes
  • Central location in Vienna with excellent accessibility

 

Book Your Appointment Today!

Contact us for a non-binding quote or an initial consultation:

  • E-Mail: roland.palkovich@becom-group.com
  • Phone: +43 1 914 20 91 - 751
  • Address: Gutheil-Schoder-Gasse 17, 1230 Vienna

 

divider

Testing of electric drives under load – EMC testing for drive systems up to 400 kW – Generator operation – Motor operation – Axle operation

  • Emission & Immunity EMC Measurements Under Load
  • Electrical load: max. power 400 kW (200 kW per side)
  • Maximum cooling capacity for the device under test: 32 kW
  • Maximum torque: 3300 Nm per side
  • Maximum speed: 1800 rpm per side

 

UN/ECE R10 – EMC type approval for vehicle components – We are a Technical Service!

  • Technical Service for ECE R10 Component Testing
  • Pre-Compliance Vehicle Measurements

 

EMC Testing for Heavy-Duty Automotive Components (E-Motors, HV Batteries)

  • Test benches for loads up to 600 kg
  • Cranes up to 1000 kg
  • Special EMC emission & immunity tests

 

divider

We offer much more!

EMV Automotive, EMV Industry, EMV Railway
EMV Automotive, EMV Industry, EMV Railway

In addition to our comprehensive EMC testing and technical assessments, we offer a wide range of other EMC-related services.

Whether it’s customized test concepts, special measurements, advice on EMC-compliant design, or support with CE marking – we are your competent partner.

Contact us – we will be happy to provide you with personal information about all possibilities and prepare a tailored offer to meet your requirements.

 

Our Services at a Glance:

  • Conducted emissions
  • Radiated emissions
  • Immunity against ESD, Burst, Surge, Magnetic field, High-frequency disturbances
  • Magnetic field measurements – 0 Hz to 400 MHz
  • Pre-Compliance tests
  • Consulting for EMC-compliant product development – schematic analysis
  • EMC PCB and layout support & evaluations
  • EMC fault analysis
  • Shielding attenuation measurements

 

divider

Precision across more than 1,000 m²

Unser Labor ist mit hochwertigen Messgeräten ausgestattet und bietet modernste Infrastruktur für EMV-Prüfungen. Auf einer Fläche von mehr als 1.000 m² stehen spezialisierte Bereiche für HF-Emissionstests (Messung abgestrahlter Störungen), Immunitätstests (Störfestigkeitsprüfungen nach internationalen Normen) sowie Elektrische Tests (Leitungsgebundene Störungen, Spannungseinbrüche, Transienten) zu Verfügung.

Dazu zählen:

3 m Absorberkabine

5 m Absorberkabine

  • 3 m Messdistanz
  • 4 m Höhenscan
  • 32 kW Lastmaschine für E-Antriebe

 

  • 5 m Messdistanz
  • 4 m Höhenscan
  • 400 kw Lastmaschine für E-Antriebe
  • EMV-Test für Fahrzeuge (Pre-Compliance)
  • 5000 kg Bodenbelastung

Automotive Absorberkabine

Schirmkabine 1

  • 1 m Messdistanz
  • 32 kW Lastmaschine für E-Antriebe
  • 500 kg Bodenbelastung

 

  • Funktion der Modenverwirbelungskammer (Reverberation Chamber) ist bereit
  • 400 kW Lastmaschine für E-Antriebe
  • Abmessungen: 7 m x 5 m
  • Eingang: 3 m Tür
  • 2000 kg Bodenbelastung

Schirmkabine 2

Testbereiche für ESD

  • Leitungsgebunden Messungen
  • Schirmdämpfungsmessungen für Materialien

 

  • Zwei Bereiche
  • Regulierung von Luftfeuchtigkeit und Temperatur

Mobile Testplätze

Equipment

  • 7 Testplätze
  • Leitungsgebunde Tests
  • Elektrische Tests – Automotive sowie Commercial
  • Netzwerkanalysatoren
  • Spektrumanalysatoren
  • EMV-Receiver
  • ESD-Generatoren und Burst-/Surge-Simulatoren
  • Automotive Puls-/Signal-generatoren
  • Load Dump
  • Netznachbildungen/Koppelnetzwerke
  • Klimakammer (350 L)
  • LF-Leistungsverstärker
  • HF-Generatoren sowie HF-Leistungsverstärkern
  • Equipment für EMV-Debugging
  • Equipment zur automatisierten Prüflingsüberwachung
  • Kammerasysteme mit Mikrofon

 

 

divider

Location – EMC Laboratory Vienna

Calculate your route:

From Munich to the EMC Laboratory: 50 minutes by plane & 260 minutes by car.
Scroll to page top